BeamOn HR-Laser Beam Analysis

BeamOn HR-Laser Beam Analysis

1.4 Megapixel CCD Beam profiler, 12 Bit resolution. A complete test station measuring Profile, Power and Position, both for CW and Pulsed beams. Based on a USB 2.0 interface for notebooks. Offered with a complete set for larger beams and high power attenuation.

The BeamOn HR system is a beam diagnostics measurement system for real-time measurement of CW or Pulsed laser beams. It provides laser beam parameters, such as: beam width, shape, position, power, and intensity profiles. Software also provides report function for beam analysis settings and results (see an example on Downloads).

The BeamOn HR is based on a USB 2.0 CCD Camera, software driven device, which can be connected to a Notebook (or Desktop) computer via the High Speed USB 2.0 port and run on Windows 7 / 8 / 10 OS (32 & 64 bit).

*New feature: Built-in motorized filter wheel controlled by software (or ActiveX) further widening the optical bandwidth.

Specifications

Parameters Value
Camera type Monochrome interline transfer progressive scan,1.4MP CCD 1/2″format
Sensor active area 6.47mm×4.83mm
Pixel size 4.65um×4.65um
Max frame rate 15fps at 1392×1040,30fps with binning(2×)
Image resolution 1392×1040
Spectral response 350~1310nm
Weight 165 gr
Power consumption 6V,4Watts
Accessories included Filter wheel with 3×NG Schott colored filters (NG4,NG9,NG10) in housing.Adaptor ring for user filter.Mounting post
Mounting consumption 3/4″×32 when filter wheel removed
Shutter speed 0.6sec to 1usec
Gain Control ×1 to ×23
Dynamic range 60dB not include filters
Sensitivity 5nW/cm2@633nm,60uW/mm2@1310nm
Saturation intensity 2mW/cm2
Damage threshold 50W/cm2  with  filters
Operation with pulse lasers: Abillty to capture and replay image from slowly pulsing laser(1~100Hz)while filtering out frames with no laser pulse.Gain control and external filter make it easy to abtain optimal intensity
Trigger in RCA female jack,4.5V squre wave TTL
Hardware triggering: In pulse mode set threshold by slide bar to display frames with captured pulse

 

BeamOn IR-1550nm spec:
Spectral response 1550nm±50nm
Sensitivity 22uW/mm2
Saturation 10mW/mm2

 

Ordering Information

  • BeamOn HR: A camera for 350 – 1310nm, a standard USB2.0 cable, a post, a set of 3XND filters in housing on a built-in filter wheel (removable), software on CD disk, carrying case.
  • BeamOn HR 1550: A camera for 1550nm+/-50nm
  • BeamOn HR-AFW: Built in Motorized automatic filter wheel.

 

Additional accessories

SAM1 Beam sampler (ratio 3X10^(-3))

SAM2 Beam sampler (ratio 1X10^(-6))

SAM3-A: Beam sampler polarization preserving (ratio 0.0016 Avg)

RDC Beam reducer (ratio 2X1)

RDC-FILT: 1/8 ND filter, M37X0.75

MOUNTB: Mounting base

NG-Filters: 1.6mm thick Schott colored filter in housing with adaptor, types: NG4/NG9/NG10

Adapter: C-Mount adapter ring

Reviews

There are no reviews yet.

Be the first to review “BeamOn HR-Laser Beam Analysis”

Your email address will not be published. Required fields are marked *